Details Images
120mm Cast iron burner +130mm Steel Cap, 4.2kW
7mm thickness tempered glass, 2D
Matt black Iron Pan support
1 | Panel: | 7mm thickness tempered glass, 2D |
2 | Panel Size: | 730*410mm |
3 | Bottom body: | 0.4mm black painting Iron sheet bottom body |
4 | Hole size: | 650*350mm |
5 | Left Burner: | 120mm Cast iron burner +130mm Steel Cap, 4.2kW |
6 | Middle Burner: | 3# Sabaf Burner, 75mm Iron cap,1.75kW |
5 | Left Burner: | 100mm Cast iron burner +130mm Steel Cap, 4.2kW |
8 | Pan support: | Matt black Iron Pan support +small pan support |
9 | Water Tray: | Stainless steel water tray |
10 | Ignition: | Battery pluse with 1.5V*1, |
11 | Gas pipe: | Aluminum gas pipe |
12 | Knob: | Metal Knob, Silver color |
13 | Footstand: | 28mm height PVC |
14 | Packing: | 5 Layer strong Brown box with strong polyfoam |
15 | Gas Type: | LPG |
16 | Carton Size: | 760*460*195mm |
17 | Loading QTY: | 20GP: 450pcs, 40HQ: 1060cs |
Model Selling Points?
What is the phenomenon of flame separation? What are the main causes and how to deal with them?
One third of the flame breaks away from the fire hole and generates a whirring sound. The main causes and treatment methods are as follows:
1. Too much primary air or poor regulation of the damper can be achieved by regulating the damper;
2. The applicable gas source of the cooker is inconsistent with the user's gas source, replace the cooker or change the gas source;
3. Some fire cover holes are blocked, and the fire cover holes are transmitted;
4. The pressure of the air source is too high or the pressure reducing valve is poor.
What is the phenomenon of tempering? What are the main causes and how to deal with them?
The phenomenon that the flame burns inside the burner, and there will be a lot of combustion noise. The main causes and treatment methods are: 1. There is dirt in the fire hole, and the dirt should be removed; The fire cover is not in place, and it should be put again; 2. If the pressure output is low, adjust the gas pressure of the pressure reducing valve; 3. The rubber hose is squeezed to eliminate extrusion; 4. Adjust the air valve to normal combustion state if it is too large;
What are the requirements for the gas connection pipe of the cooker?
The gas hoses that meet the national standards and pass the inspection shall be used, and the connection must be locked with a special buckle; Hard connected metal hoses shall be used as far as possible.
The stove has no sound of ignition. What is the reason for ignition failure?
1. The battery is dead, replace the battery; 2. The microswitch is damaged; 3. The igniter is damaged; 4. Ignition pin fault.